Nutanix Acropolis Base Software 4.5 (NOS release)…be still my heart!

Today Nutanix announced the release of “Acropolis Base Software” 4.5…the software formerly known as NOS.  I happened to be in the Nutanix Portal this morning and didn’t even notice the release in the “Downloads” section due to the name change…thankfully @tbuckholz was nice enough to alert me to this wonderful news.

smiley-with-heart-shaped-eyes

I read through the Release Notes and was pretty excited with what I found – a bunch of new features that solve some challenges and enhance the environment I’m responsible for caring and feeding on a daily basis.  Some of these features I knew were coming, others were a surprise.  There’s a ton of good stuff in this release so I encourage you to check them out for yourself.

A short list of some of the things particularly interesting to me in no particular order…

  1. Cloud Connect for Azure – prior to this release, Nutanix Cloud Connect supported AWS…it’s good to have options.  I was actually having a conversation with a coworker yesterday about the possibility of sending certain data at our DR site up to cloud storage for longer / more resilient retention.

    The cloud connect feature for Azure enables you to back up and restore copies of virtual machines and files to and from an on-premise cluster and a Nutanix Controller VM located on the Microsoft Azure cloud. Once configured through the Prism web console, the remote site cluster is managed and monitored through the Data Protection dashboard like any other remote site you have created and configured. This feature is currently supported for ESXi hypervisor environments only. [FEAT-684]

  2. Erasure Coding – lots of good info out there on this feature that was announced this summer so I won’t go into too much detail.  Long story short it can allow you to get further effective capacity out of your Nutanix cluster.  A lower $ : GB ratio is always welcome. @andreleibovici has a good blog post describing this feature at his myvirtualcloud.net site.

    Erasure CodingComplementary to deduplication and compression, erasure coding increases the effective or usable cluster storage capacity. [FEAT-1096]

  3. MPIO Access to iSCSI Disks – another thing I was fighting Microsoft support and a couple other misinformed people about just last week.  One word:  Exchange.  Hopefully this will finally put to rest any pushback by Microsoft or others about “NFS” being “unsupported”.  I spent a bunch of time last week researching the whole “NFS thing” and it was a very interesting discussion.  @josh_odgers spent a lot of time “fighting the FUD” if you will and detailing why Microsoft should support Exchange with “NFS” backed storage.  A few of my favorite links THIS, THIS (my favorite), and THIS WHOLE SERIES.

    Acropolis base software 4.5 feature to help enforce access control to volume groups and expose volume group disks as dual namespace disks.

  4. File Level Restore (Tech Preview) – this was one of the “surprises” and also one of my favorites.  We are leveraging Nutanix Protection Domains for local and remote snapshots for VM level recovery and Veeam for longer term retention / file based recovery.  However, the storage appliance that houses our backup data can be rather slow for large restores so the ability to recover SOME or ALL of a VM using the Nutanix snapshots I already have in place is a big deal for me.

    The file level restore feature allows a virtual machine user to restore a file within a virtual machine from the Nutanix protected snapshot with minimal Nutanix administrator intervention. [FEAT-680]

  5. Support for Minor Release Upgrades for ESXi hosts – this is nice for those random times that you need to do a minor revision upgrade to ESXi because “when ____ hardware is combined with ______ version of software ______, ______ happens”.  We’ve all been there.  Nutanix still qualifies certain releases for one click upgrade, but there is now support for upgrades using the Controller “VM cluster” command.

    Acropolis base software 4.5 enables you to patch upgrade ESXi hosts with minor release versions of ESXi host software through the Controller VM cluster command. Nutanix qualifies specific VMware updates and provides a related JSON metadata upgrade file for one-click upgrade, but now customers can patch hosts by using the offline bundle and md5sum checksum available from VMware, and using the Controller VM cluster command. [ENG-31506]

It’s always nice to get “new stuff” with a super simple software upgrade.  Thanks for taking the time to read and I encourage you to check out some of the other features that might be of interest to your environment.

Veeam + Nutanix: “Active snapshots limit reached for datastore”

Last night I ran into an interesting “quirk” using Veeam v8 to back up my virtual machines that live on a Nutanix cluster.  We’d just moved the majority of our production workload over to the new Nutanix hardware this past weekend and last night marked the first round of backups using Veeam on it.

We ended up deploying a new Veeam backup server and proxy set on the Nutanix cluster in parallel to our existing environment.  When there were multiple jobs running concurrently overnight, many of them were in a “0% completion” state, and the individual VM’s that make up the jobs had a “Resource not ready: Active snapshots limit reached for datastore” message on them.

veeam 1

I turned to the all-knowing Google and happened across a Veeam forum post that sounded very similar to the issue I was experiencing.  I decided to open up a ticket with Veeam support since the forum post in question referenced Veeam v7, and the support engineer confirmed that there was indeed a self-imposed limit of 4 active snapshots per datastore – a “protection method” of sorts to avoid filling up a datastore.  On our previous platform, the VM’s were spread across 10+ volumes and this issue was never experienced.  However, our Nutanix cluster is configured with a single storage pool and a single container with all VM’s living on it, so we hit that limit quickly with concurrent backup jobs.

The default 4 active snapshot per datastore value can be modified by creating a registry DWORD value in ‘HKEY_LOCAL_MACHINE\SOFTWARE\Veeam\Veeam Backup and Replication\’ called MaxSnapshotsPerDatastore and use the appropriate hex or decimal value.  I started off with ’20’ but will move up or down as necessary.  We have plenty of capacity at this time and I’m not worried at all about filling up the storage container.  However, caveat emptor here because it is still a possibility.

This “issue” wasn’t anything specific to Nutanix at all, but is increasingly likely with any platform that uses a scale-out file system that can store hundreds or thousands of virtual machines on a single container.

NetScaler 10.5 – fsck commands have changed

Just a heads up in case anyone else runs into this, the process for verifying the file system integrity of a NetScaler appliance has apparently changed in the 10.5 firmware, but Citrix’s documentation does not (yet) reflect this.

We had a “surprise network outage” over the weekend which took down iSCSI connectivity, and with it, my NetScaler VPX HA pair.

images

Shortly after everything came back up, we began receiving alerts from NetScaler Command Center that “hardDiskDriveErrors” are seen on the system.

nserror

Alright, fine, let’s verify file system integrity and see what there is to see.  Citrix article CTX122845 outlines the process…or so I thought.  I’d never done this/had to do this before, so I couldn’t compare to a past experience.

In Step 5, you are told to press enter after booting to single user mode and the command prompt of the appliance changes to “\u@\h$” but it doesn’t…just “\u@”.  Then, in Step 6 you are directed to enter the “/sbin/fsck /dev/######” command.  However, that command didn’t work either.

I opened a ticket with Citrix support to rule out a PEBKAC error (quite likely if I’m involved) and they confirmed these commands indeed do not work, and they’ve actually changed in the NS 10.5 firmware.

In this screenshot, we see the error when attempting to enter the command according to Step 6 in CTX122845

ns2

Here is an example of the correct command “\u@fsck -t ufs /dev/######”

ns1

Also, be sure to check out what your actual device names are according to CTX121853, it does vary by model and in the case of the VPX, differs from the example used in CTX122845.

Hopefully Citrix will update their documentation soon, but if not, this might be your work around.

A tale of two firmware upgrades…

On this fine Friday afternoon, I thought I’d have a little fun comparing and contrasting the firmware upgrade process on two different storage solutions. We recently bought some Nutanix 8035 nodes to replace the existing storage platform. While I wouldn’t necessarily call Nutanix “just” a storage platform, the topic of this discussion will be the storage side of the house. For the sake of anonymity, we’ll call our existing storage platform the “CME XNV 0035”.

One of the biggest factors in choosing the Nutanix platform for our new compute and storage solution was “ease of use”. And there’s a reason for that – the amount of administrative effort required to care and feed the “CME XNV 0035” was far too high, in my opinion. Even a “simple” firmware upgrade took days or weeks of pre-planning/scheduling and 8 hours to complete in our maintenance window. Now that I’ve been through the firmware upgrade on our Nutanix platform, I thought a compare and contrast was in order.

First, let me take you through the firmware upgrade on the “CME XNV 0035”

  1. Reach out to CME Support, open a ticket, and request a firmware update. They might have reached out to you proactively if there was a major bug/stability issue found. (Their product support structure is methodical and thorough, I will give them that) 30 minutes
  2. An upgrade engineer was scheduled to do the “pre upgrade health check” at a later date.
  3. The “pre upgrade health check” occurs, logs and support data are gathered for later analysis. Eventually it occurred frequently enough I’d just go ahead and gather and upload this data on my own and attach it to the ticket. 1 hour
  4. A few hours to a few days later, we’d get the green light from the support analysis that we were “go for upgrade”. In the mean time, the actual upgrade was scheduled with an upgrade engineer for a later date during our maintenance window…typically a week or so after the “pre upgrade health check” happened.
  5. Day of the upgrade – hop on a Webex with the upgrade engineer, and begin the upgrade process.  Logs were gathered again and reviewed.  This was a “unified” XNV 0035, though we weren’t using the file side…..I’m…..not sure why file was even bought at all, but I digress….which meant we still had to upgrade the data movers and THEN move onto the block side.  One storage processor was upgraded and rebooted…took about an hour, and then the other storage processor was upgraded and rebooted…took another hour.  Support logs were gathered again, reviewed by the upgrade engineer, and as long as there were no outstanding issues, the “green light” was given.  6-8 hours

Whew……7.5 – 9 hours of my life down the drain…

download

Now, let’s review the firmware upgrade process on the Nutanix cluster

  1. Log into Prism, click “Upgrade Software” 10 seconds
  2. Click “Download” if it hasn’t done it automatically 1 minute (longer if you’re still on dial up)
  3. Click “Upgrade”, then click the “Yes, I really really do want to upgrade” button (I paraphrase) 5 seconds
  4. Play “2048”, drink a beer or coffee, etc. 30 minutes
  5. Run a “Nutanix Cluster Check (NCC)”
  6. Done

There you have it, 31 minutes and 15 seconds later, you’re running on the latest firmware.  Nutanix touts “One click upgrades”, but I counted four, technically.  I can live with that.

Yes, this post is rather tongue in cheek, but it is reflective of the actual upgrade process for each solution.  Aside from the initial “four clicks”, Nutanix handles everything else for you and the firmware upgrade occurs completely non-disruptively.

unnamed

VMware NSX Lab Environment – Part 2: Prepare Hosts and Deploy NSX Controllers

Introduction

In Part 2 of this series I will cover preparing the ESXi hosts for NSX and deploying an NSX Controller cluster.  As mentioned in the first part of this series “Part 1:  Import and Configure NSX Manager“, the NSX Manager facilitates the deployment of the Controller clusters and ESXi host preparation (among other things), so needless to say having it up and functioning is a prerequisite for this phase.

At the completion of this post, the NSX environment should be mostly configured and we will be able to start doing fun stuff like deploying logical switches, setting up distributed routing, and playing with distributed firewall rules.  I’m pretty excited. /geekout

As you may have gathered by their name, the NSX Controllers reside in the “Control plane” while the NSX Manager resides in the “Management plane”.  Services such as logical switches, distributed logical routers / firewalls are all hypervisor kernel modules and reside in the “Data plane”.  NSX Edge, a virtual appliance(s) also resides in the data plane.  The focus of this post will be the Control plane.

This diagram, courtesy of the VMware NSX 6 Design Guide, depicts the various “planes” in which NSX components reside.

Controller Deployment 2

Deploying the NSX Controllers

1. Now that NSX Manager is running and linked to your vCenter server, the next step in the process would be to enter your NSX licenses.  However, since this is a lab I am running it in evaluation mode for 60 days, I have nothing to enter here.  If you do own the product, or are lucky enough to have a license key for perpetual lab purposes, you’d just go to “Administration > Licensing > Licenses” in the vSphere Web Client and enter the appropriate license keys.

Controller Deployment 1

2. After you’re licensed (or running in eval mode), it’s time to deploy the NSX Controllers.  Under “Networking and Security”, click “Installation.

Controller Deployment 3

3. Click the green “+” sign underneath “NSX Controller nodes”…

Controller Deployment 4

…and you will be asked to enter vSphere cluster, storage, and networking info.

Controller Deployment 5

Click “Select” next to “IP Pool”.  If you’ve already created one you’d like to use, select it and then click “OK”.  Otherwise, click the green “+” and add a new IP Pool.  Once you’ve entered the details appropriate to your environment, click “OK” on the “Add IP Pool” window, select the radio button next to your new IP Pool, and then click “OK” again on the “Select IP Pool” window.

I’ve created a 10 address IP pool for the NSX Controllers to use – technically you’d only need as many IP addresses as you’d have NSX Controllers, but I get kind of OCD about that sort of thing so I’ve allocated a block of 10.  IP’s are one of the few things I have an abundance of in the lab environment.

Controller Deployment 6

4. Click “OK” on the “Add Controller” window.

** It’s worth noting – the NSX Controller password requirements are fairly strict.  My “lab password” I’ve been re-using throughout the environment did not meet the length requirement and it complained…as you see here.  I have a feeling this is one of those passwords you don’t want to lose so be sure to keep it somewhere safe.

Controller Deployment 7

Assuming everything is good with your configuration, NSX Manager should begin deploying the Controllers to your vSphere environment using the supplied credentials linking it to vCenter (as you can see in the “Initiated by” column under “Recent Tasks”).  It’s also worth noting that the NSX Controllers get a unique identification string appended to them – avoid the urge to modify this – it’s by design.  (And yes, I did just throw a screenshot of the “fat”/C# client in here…I do catch myself flipping back to it from time to time.  It’s a habit I’m working on breaking 😛 )

Controller Deployment 8

5. Once the Controller deployment has completed, it should show a “Normal” status in the vSphere Web Client window.  If that’s the case, it’s fairly safe to say subsequent Controller deployments will be successful, so you can now repeat this process 2 more times in order to meet the “3 Controller node minimum” recommendation.  NSX Controllers should be deployed in odd numbers so that a “majority vote” can occur for electing a Master controller.

**You will not be prompted to enter a Controller password again on subsequent Controller deployments – this is shared between all NSX Controllers in the Controller cluster.

Controller Deployment 9

The Controllers are clustered?  Yes, they are.

Without going in too much detail (the NSX Design Guide does a great job explaining it), the “responsibilities” of an NSX Controller get distributed among all members of the Controller cluster.  A Master Controller is responsible for determining when a Controller node has failed and where the “slices” of a particular role it held should be transitioned to.

This image, courtesy of the VMware NSX Design Guide, shows the number of nodes that can fail for a particular NSX Controller cluster count.

2015-04-27 13_25_03-NSX 6 Design Guide.pdf - Adobe Reader

6. In this step, we will create “anti-affinity” rules for the NSX Controllers to ensure no two Controllers ever reside on the same host.  This is an important step in mitigating impact to the NSX environment if an ESXi host fails.  For a lab environment it’s probably not a big deal but I felt it was important to show, as I frequently see vSphere environments with no DRS rules setup when they should probably be used for resiliency of redundant guest VM’s.  As has been commented on by others, I’m kind of surprised that the creation of the anti-affinity rule isn’t done by NSX Manager automatically when deploying two or more Controllers.  I believe other components, such as NSX Edges, do have a rule created by default…perhaps I’m mistaken and will find out shortly.

Anyhow…

In the vSphere Web Client, navigate to the “Hosts and Clusters” view, select the applicable vSphere cluster, then click the “Manage” tab.  Select “VM/Host” Rules and then click “Add”.

Controller Deployment 10

7. Give your DRS Rule a name – I usually like to get descriptive about the nature of it (i.e. add “Anti-Affinity”) in the name.  Click the “Add” button, select your NSX Controllers, and click “OK”.  Click “OK” once more on the “Add VM/Host Rule” window.

DRS Rules 2

8. Now we will prepare the ESXi hosts for NSX.  Click on the “Host Preparation” tab and then select “Install” next to the appropriate cluster(s).  When prompted, click “Yes” to continue with the install.

Controller Deployment 12

If the host preparation was successful, you should see a green checkmark underneath the “Installation Status” and “Firewall” columns.

Controller Deployment 13

9. The next step is to configure VXLAN on our NSX enabled cluster.  On the “Host Preparation” tab, under the “VXLAN” column, select “Configure”.  You will need to select a Distributed Virtual Switch for VXLAN traffic (I’ve created one dedicated for that purpose with a single vNIC uplink…hey, it’s a lab), enter the appropriate VLAN, set your MTU size (it’s not recommended to go below 1600 due to the ~50 byte VXLAN header addition) so make sure your underlying physical (or in this case, virtual) network is configured for jumbo frames.

I’m going to create an IP pool dedicated for VTEP’s so I’ve selected “New IP Pool…” from the drop down box.

Controller Deployment 14

Enter the appropriate IP Pool information here, then click “OK”.  Like the IP Pool I created for the NSX Controllers, this one has 10 IP addresses in it.  You will need a pool large enough to provide IP addresses for each VTEP (VXLAN Tunnel End Point) interface on each host in that IP space.

Controller Deployment 15

Click “OK” in the “Configure VXLAN networking” window.

At this point, we should have green checkmarks across the board on our “Host Preparation” tab.

Controller Deployment 16

** There are considerable design decisions that must be made when choosing your VMKNic Teaming Policy – the layout of your physical networking and Distributed Virtual Switch uplink configuration could dictate which options are viable.  The VMware NSX Design Guide goes over this in great detail (beginning around page 73) and is worth the read.

This table courtesy of the VMware NSX Design Guide shows the teaming and failover modes available based on the uplink type.

Controller Deployment 17

10. The next step is to create a Segment ID (which I believe is also sometimes called a VXLAN Network Identifier/VNI) Pool.  I like to think of Segment ID’s like special VLAN’s inside of the NSX environment – they are used to differentiate the various logical network segments just like VLAN’s on a physical switch logically segment the traffic.  NSX let’s you specify a range of 5,000 to 16,777,216…so roughly 16 million possibilities.  The range you specify in your Segment ID Pool will dictate the maximum amount of logical switches available to your NSX environment.

Under the “Installation” section, click the “Logical Network Preparation” tab and select the “Segment ID” section.  Click “Edit” next to “Segment IDs & Multicast Address allocation…”

Controller Deployment 18

11. Specify your Segment ID Pool range.  I chose 5000-5999, which gives me 1000 possible network segments…far greater than I’d ever need in a lab, but hey why not?

Controller Deployment 19

** I’ve not checked the option to “Enable multicast addressing” and am relying on Unicast for my BUM traffic (Broadcast, Unknown, Unicast, and Multicast).  Not to sound like a broken record, but there are considerable design decisions you’d make to determine whether or not to use Multicast, Unicast, or Hybrid modes.  Page 25 of the VMWare NSX Design Guide goes into detail about the pros and cons of each, when to use or not use, etc.  This is not something I ever had to give much thought to in my “server centric” world prior to starting down the NSX wormhole, and found it one of the harder concepts to grasp and remember when studying for the VCP-NV exam.  This is an area I am still shoring up because it’s directly related to the way NSX propagates information throughout the environment, so it’s obviously a critical piece.

12. The final piece is to configure our Transport Zone.  What is a Transport Zone you ask?  Well, per VMware, it quite literally “defines a collection of ESXi hosts that can communicate with each other across a physical network infrastructure.”  In other words, it determines which cluster(s) participate in the NSX environment.

Click on the “Transport Zones” section, then the green “+” sign.

Controller Deployment 20

Give the Transport Zone a name, select the appropriate replication mode, and the cluster(s) you wish to be included in the Transport Zone.  Click “OK”.

Controller Deployment 21

12. At this point, all the NSX Controllers and supporting configuration should be in place.  Review each tab under “Networking and Security > Installation > Logical Network Preparation” to ensure everything looks correct.

Controller Deployment 22

Controller Deployment 23

Controller Deployment 24

If so, we’re ready to do all the fun stuff you really wanted to deploy NSX for.  The next post in this series will handle the configuration of logical switching, distributed routing, and Edge Services.  A couple of the big things I’m looking to demonstrate are isolation of mock customers in a multi tenant environment and securing a VDI deployment with NSX.

Being my first go-round installing NSX, if you see any inaccuracies or a better way of doing things, please let me know.  And as always, thanks for reading!

 

VMware NSX Lab Environment – Part 1: Import and Configure NSX Manager

Introduction

This blog series will cover the installation and configuration of VMware NSX 6.1.3 in a lab environment.  As such, there are certain design considerations I am overlooking because this is not a production deployment and lab resources are somewhat limited.  It goes without saying a production deployment may and should look a little different 😉

An example of this would be to distribute the vSphere and NSX infrastructure into multiple clusters – a “Management” cluster which might house vCenter, NSX Manager, and the NSX Controllers; an “Edge” cluster which might house things like the NSX Edge Services Gateway and the Distributed Logical Router (DLR) / DLR Control VM, which control the flow of L2 (NSX Bridging) or L3 traffic (NSX Logical Routing) into and out of the NSX logical networking environment; and a “Compute” cluster where the bulk of your server and/or desktop virtualization workload would live.  In a production deployment, these clusters may even span two or more racks to provide resiliency of all workloads in the event of a rack loss.

Example of “dispersed clusters” courtesy of VMware Hands on Labs (Management/Edge cluster + Compute cluster):

NSX Clusters

However, my purpose for deploying NSX in my lab is to get more hands on exposure to the product and as a “proof of concept” for the various capabilities of NSX.  While important to know all the design considerations, it’s not particularly important in THIS instance.

I highly recommend familiarizing yourself with the NSX Design Guide – it’s a great piece of reference material.  I read it start to finish as part of studying for the VCP-NV exam and largely attribute its content, in combination with the VMware Hands on Labs, for passing the exam.  The NSX Design Guide can be found HERE.

The Lab Environment

I will also not be covering the installation and configuration of the various vSphere 6.0 infrastructure that all the NSX components ride upon.  There are many great blogs and white papers covering this, and let’s be honest – if you’re looking to lab out NSX, you probably already have vSphere configuration down pat.

This NSX lab environment exists on a nested ESXi cluster running vSphere 6.0.  There are three ESXi 6.0 virtual machines, each with 24 GB of RAM, 4 vCPU, and ~200 GB of “local” storage across multiple datastores (a couple of which will be used for VSAN at a later date).  A vCenter Server Appliance 6.0 was imported into the nested environment and runs on top of the virtualized ESXi hosts.  Running a nested hypervisor gives you a lot of flexibility on the hardware which it runs on (and flexibility for isolation if desired, to avoid screwing important stuff up 😛 ), so this could just as easily run on top of a couple “home lab” type boxes without issue.

William Lam (@lamw on Twitter) has a GREAT series of posts on his blog virtuallyGhetto.com detailing the requirements and configuration for running nested ESXi – I highly recommend checking it out.  In fact, the 3-node ESXi cluster I am using for this blog post was deployed from an .OVF file he’s made available to the community.  Check out his Nested ESXi Series here and VSAN .OVF Template series here.  I’ve configured this lab environment to be 100% isolated to the outside world from a network, storage, and hardware perspective…which gives me some freedom to make changes and mistakes without breaking anything I care about.

There’s probably many (and better) blogs covering this same subject, but hey, I need the blogging practice anyway so maybe someone will find it useful…so thanks in advance for reading.

And without further ado, importing and configuring NSX Manager.

Import the NSX Manager

The first step in getting NSX running in your environment is to install and configure the NSX Manager.  The NSX Manager is a virtual appliance that is responsible for deploying all the other components of NSX such as the NSX Controllers, Edge Gateways, etc.

There is a 1:1 relationship between a NSX Manager and a vCenter server – one NSX Manager serves a single vCenter Server environment.

** As stated in the NSX Installation Guide, the NSX Manager virtual machine installation includes VMware Tools.  Do not attempt to upgrade or install VMware Tools on the NSX Manager.  One of the first things I noticed (and felt compelled to do) once the NSX Manager was running is to get rid of the angry yellow “VMware Tools is outdated on this virtual machine” warning on the NSX Manager VM Summary tab.  Fight the urge and leave it at the included VMware Tools level.

NSX Manager 1

1. Deploying the NSX Manager must be done through the vSphere Web Client instead of the C# client due to some “extra configuration options” that are only present in the Web Client. Right click on your vCenter Server and select “Deploy OVF Template”.

** You must have the Client Integration Plugin installed in order to deploy an OVF through the vSphere Web Client.  I’ve had issues with the plugin and Internet Explorer 11, so I recommend running this through Chrome or Firefox until/if those issues are resolved.

NSX Manager 2

2. Browse to your .OVA file.  Mine is on an .ISO mounted in the virtual DVD drive of the virtual “jump box” workstation I access my lab environment from.  Click “Next”.

NSX Manager 3

NSX Manager 4

3. On the “Review details” screen, select the “Accept extra configuration options” check box (this option wouldn’t be presented in the C# client, and then you’d have issues with your NSX Manager).

NSX Manager 5

4. Accept the EULA, blah blah blah, then click “Next”.

NSX Manager 6

5. Select a name for the NSX Manager – I got super creative with mine and left it “NSX Manager” – select a folder/location, then click “Next”.

NSX Manager 7

6. Select a cluster or host, then click “Next”.

NSX Manager 8

7. Select a disk format.  I chose “Thin Provision” since this is a lab and storage is at a premium right now.  If necessary, change your VM Storage Policy.  While this lab will have VSAN configured in it eventually, it does not now, and I’m installing on “local” storage (in quotes because it’s actually a .VMDK file on a SAN LUN) of my ESXi host, so I’ve left it at “Datastore Default”.  Click “Next” once you’ve selected the appropriate storage settings for your environment.

** Another shout out to William Lam (@lamw) and his blog www.virtuallyghetto.com for the super handy nested ESXi VSAN OVF templates from which this lab cluster was deployed.

NSX Manager 9

8. Now it’s time to select a network for your NSX Manager.  Right now I’m using the default “VM Network” that was created when I installed ESXi, but I’m essentially treating it as my management network for management/vMotion VMkernel interfaces.  I’ll have some other network interfaces for VXLAN traffic etc. which will be setup at a later time.  Once you have selected the appropriate network, click “Next”.

NSX Manager 10

9. The “Customize template” window has quite a bit for you to fill in – there are some passwords for various purposes on the NSX Manager, IP/DNS/network settings, etc.  Fill in the info as it applies to your environment, then click “Next”.

NSX Manager 11

10. On the “Ready to complete” screen, verify all your information is correct before clicking finish.  If everything looks good, click “Finish”.  The NSX Manager virtual appliance will now be deployed and powered on automatically (if selected).

NSX Manager 12

Configure the NSX Manager

1. Once the NSX Manager appliance has finished booting and is online, log into the NSX Manager appliance to resume configuration.  You will have specified this IP address in Step 9.  Example https://172.16.99.150.  The credentials used for login will also have been specified in Step 9.  Username: admin Password: [user defined].  If you did not define a password during installation, it should be “default”.

NSX Manager Home

2. The first thing to do is check that all the necessary services are running…if they’re not…you won’t get much further.  Click the “View Summary” button to be taken to the appliance summary page.  All services should show “Running”, with possibly exception to the “SSH Service”.

NSX Summary

 

NSX Summary 2

3. Now we will register NSX Manager with your vCenter Server.  Click the , click “Manage” tab, and then click “NSX Management Service” under the “Components” menu section.

NSX Manager 14

Click “Edit” to enter your vCenter Server details

NSX Manager 15

4. Enter the appropriate credentials to connect to your vCenter Server.  Yeah yeah yeah, I used my personal lab account instead of a service account…so what?!  Click “OK” and you should be prompted to trust the vCenter Server certificate.  Click “Yes” on this window.

NSX Manager 16

NSX Manager 17

 

**Update**

I ended up ditching using my “personal” lab account for the vCenter connection…not exactly sure why yet, but whenever I logged into vCenter it showed a “No NSX Managers available” error.  I switched to a new “service” account that also has Administrator rights in vCenter and the NSX Manager populated correctly.  It even showed my “personal” account listed as an NSX Enterprise Administrator but I could not see anything.  After logging into vCenter with the “nsxservice” service account, I went to Networking and Security > NSX Managers > Manage > Users and deleted my personal account and re-added it as an Enterprise Administrator.  Once I did that, I was able to log into vCenter with my personal account and see the NSX Manager fine.  Who knows…perhaps I did something wrong during the initial vCenter linking.  So just a heads up in case you run into a similar issue.

nsx users 1

5. If the connection to your vCenter Server was successful, you should see a green circle next to the “Status” field.

NSX Manager 18

 

6. Next, the Lookup Service will be configured.  Click the “Edit” button in the “Lookup Service” area.

NSX Lookup Service

Enter your Lookup Service details – it’s worth noting that in vSphere 6.0, the Lookup Service port is now 443.  I had assumed it was still 7444 and ran into some errors applying the configuration.  Luckily I ran across Chris Wahl’s (@ChrisWahl) blog with a quick explanation.

NSX Lookup Service 2

As when linking your vCenter server, trust the certificate.

NSX Lookup Service 3

And you should now see a “Connected” status under the lookup service.

NSX Lookup Service 4

7. The final step for configuring NSX Manager in the lab is to make a backup of the configuration.  It is recommended to do a backup while NSX Manager is in a “clean state” so that it can be rolled back to in the event of an issue during subsequent changes.

Click “Backup and Restore” in the “Settings” menu.

NSX Manager 19

Click “Change” next to “FTP Server Settings”, then enter your FTP/SFTP server details here.  I actually don’t have an FTP server in my lab yet, so I’m going to forego a backup at this point.  I like to live on the edge anyway.  If you’d like to setup scheduled backups, there is an option to do so on this page as well…probably recommended for a production deployment.

NSX Manager 20

8. At this point, configuration of NSX Manager is complete and it has been linked to your vCenter Server.  You should now be able to log into the vSphere Web Client and continue with deployment of the remaining NSX infrastructure pieces.

If you’re currently logged into the Web Client, log out and then log back in and you should see a new “Networking and Security” panel.  Click on “Networking and Security”.

NSX Manager 21

It is from here that most of the NSX configuration will be managed and further NSX services and components deployed from.  The next post in this series will cover deploying and configuring the NSX Controllers.  Stay tuned and thanks for reading!

NSX Manager 22

 

Part 2:  Prepare Hosts and Deploy NSX Controllers is up!

A Tale of Two Vendors…

The topic of this blog post is a comparison of two vendors and how I feel they embrace their user (customer) communities in very different ways.

To give you some background, I spent the previous 3 or so years as a consultant focusing on desktop and application virtualization with Citrix and Microsoft products – primarily Citrix XenApp and XenDesktop on the EUC side and Microsoft Hyper-V on the hypervisor side.    However, I “cut my teeth” in virtualization back in the VMware GSX / ESX 2.5 days and was primarily interested in datacenter technologies…I guess you could say VMware was my “first love”.  Fast forward to the present, I’ve taken a new position and find myself getting reacquainted with some of VMware’s newer software that I’d neglected learning much about.  As I was trying to brush up on my skills by setting up labs, reading white papers, researching user group meetings, etc. I noticed something – VMware has all sorts of great “customer enablement” offerings that Citrix doesn’t really have a parallel solution for.

Now let me preface this by saying my intent is absolutely not to vendor bash – I like to think I’m fairly vendor agnostic.  I like Citrix, I like their products, and I had a great time implementing them (well, most of the time, at least)….but I believe they’re really missing out on the user / customer enablement side of things in several areas.

  1. User groups – I don’t think there’s much to say here that hasn’t already been said…but VMware seems to have a much more mature, organic, and community oriented user group.  As a partner, I didn’t really “get” to participate in the Citrix user group events much so perhaps my perspective is skewed…but maybe not based on comments by others.  This leads me to my second point.
  2. VMUG Advantage (http://www.vmug.com/Advantage) – $200 buys you a one year membership to VMUG Advantage, which among other things gets you 20% off certification exams (which could pay for a big chunk of the membership after a test or three), $100 discount on VMworld admission, VMware Fusion and Workstation (which I believe you get as a VCP anyway), and my personal favorite:
  3. Subscription based “evaluation” software – EVALExperience (http://www.vmug.com/p/cm/ld/fid=8792) gets you access to a ton of VMware software for non-production use.  Continuous improvement and learning is critical to staying at the top of your game and the easiest way for many to do that is with a lab…yes, you could perpetually reinstall and reconfigure every 60 or 90 days using trial software, but that gets old.  And yes, if you work for a partner there are benefits associated with that.  But for the rest of us, EVALExperience might be just what the doctor ordered.
  4. Free training and hosted labs – VMware Hands on Labs (http://labs.hol.vmware.com/HOL/catalogs/)…wow, how did I go so long without using this?  Standing up your own “home lab” is rewarding in and of itself, but sometimes it can be difficult to recreate certain “enterprise class” solutions at home.  VMware HOL has an expansive catalog of labs from “software defined datacenter” to “mobility” to “end user computing” and everything in between.  I recently took advantage of their “Introduction to NSX” lab and it was a great experience…considering you can’t download a trial of NSX for your home lab at this time, it was an easy way for me to get hands-on with NSX in pursuit of the VCP-NV certification.  Allowing VMware “users” access to this sort of training is invaluable and helps grow and enhance the skills of the people who will be the “champion” of their products in the future.

I’m a firm believer in “competition breeds innovation” and hope that Citrix sees some of the positive ways VMware has embraced their user community and comes up with something great of their own.

EMC VNX Pool LUNs + VMware vSphere + VAAI = Storage DEATH

**Cliffs notes – a bug in the VNX OE causes massive storage latency when using vSphere with VAAI enabled – disabling VAAI fixes issue**

Hello, and welcome to my very first blog post! I’ve owned this domain and WordPress subscription for nearly a year and a half and am finally getting around to posting something on it. Considering I’ve spent the last 3 years focused on end user computing, and the majority of that being done with Citrix products, I always figured my first post would be in that domain…but alas, that was not the case.

The problem…

I recently started a new gig and one of the first orders of business was untangling some storage and performance issues in a vSphere 5.5 environment running on top of a Gen 1 EMC VNX 5300.  It was reported that there was very high storage latency, often resulting in LUNs being disconnected from the hosts, during certain operations like a Storage vMotion or deploying a new VM from template.

After a general review of the environment I was able to rule out a glaringly obvious mis-configuration, so I turned to a couple useful performance monitoring tools – Esxtop and Unisphere Analyzer.  While I am by no means an expert with either tool, with a little bit of Google-fu and the assistance of a couple great blogs (which I’ll link to later in this post), I was able to get the info I needed to verify my theory – a bug involving VAAI that was supposed to be addressed in the latest VNX Operating Environment (which at the time of this posting is 5.32.000.5.215) still exists.

I started out by doing some performance baselining with VisualEsxtop (https://labs.vmware.com/flings/visualesxtop) so I could get a picture of what the hosts were seeing during operations that involved VAAI (Storage vMotion, deploy-from-template/clone, etc.)  As you can see in the below screenshot, the VNX is quite pissed off.  The “DAVG” value represents disk latency (in milliseconds) that is likely storage processor or array related.  The “KAVG” value represents disk latency (in milliseconds) associated with the VMkernel.  Obviously, the latency on either side of the equation is nowhere near a reasonable number.  Duncan Epping has a great overview of Esxtop (http://www.yellow-bricks.com/esxtop), I highly recommend you give it a read if you’re newer to the tool like I am.

1

The next step was to use EMC’s Unisphere Analyzer to get a picture of what was occurring on the storage side during these operations.  If you’re not familiar with Unisphere Analyzer, an EMC employee created a brief video on how to capture and review data with it (http://www.youtube.com/watch?v=yCMZ_N7-p7A) – it’s a relatively simple tool that you can garner a lot of valuable information from.  I used it to capture storage side performance metrics during the two following tests.

2

The first test consisted of a Storage vMotion of a VM with VAAI enabled on the host (1 Gb iSCSI to the VNX).  This test moved the VM from LUN_0 to LUN_6, starting at 9:46:44 AM and finishing at 10:01:53 AM.  If you look at the corresponding time period on the Unisphere Analyzer graph you’ll see that response time is through the roof.  While it did not occur during this test, the hosts would often lose their connection to the LUNs during these periods of high latency…not good, obviously.

These warnings always show up in the vSphere Client when this issue occurs (yeah yeah, I’m not using the Web Client for this):

3

The second test consisted of a Storage vMotion of the same VM with VAAI disabled.  This test moved the VM back to LUN_0 from LUN_6, starting at 10:04:13 AM and finishing at 10:14:03 AM.  This time, the Unisphere Analyzer data looks MUCH better.

2

Here is some an example of what Esxtop looked like during the test with VAAI disabled:

4

The LUNs with ~ 1400 read/write IO are obviously the ones involved in the Storage vMotion…notice the lack of “SAN choking”.  I re-ran this test multiple times using other LUNs with identical results…it was obvious at this point that there is still an issue with VAAI being used on this VNX OE.  Fortunately, our production datacenter utilizes 10 Gbe for the iSCSI network and Storage vMotions finish in just a minute or two.  I could see this flaw being particularly problematic in larger environments where Storage vMotion is frequent or something like VDI where VM’s are frequently spun up, tore down, or updated.

The solution…

Obviously, disabling VAAI in vSphere is a guaranteed “work around”.  I wouldn’t necessarily call this a “fix” as the VAAI feature is unusable, but it will stop the high latency and disconnects when vSphere tries to offload certain storage tasks to the array.  Once I had some hard evidence in hand, I did open up a ticket with EMC, and the support engineer was able to confirm this was indeed still a bug and has not been addressed by the latest OE version.

This VMware KB article details the process of disabling VAAI (http://kb.vmware.com/selfservice/microsites/search.do?language=en_US&cmd=displayKC&externalId=1033665).  I found that just the “DataMover.HardwareAcceleratedMove” parameter in the article had to be disabled.  The EMC support engineer also mentioned they had some success increasing the “MaxHWTransferSize” parameter while leaving VAAI enabled, but that it hadn’t worked for everyone.

You can see more information from this KB article (https://support.emc.com/kb/191685 – you may need an active support account, I had to login to view this page).  I decided to just disable VAAI and call it a day until a valid bug fix was released in some future OE version.  ***update 11/06/15*** it has come to my attention the preceding EMC KB191685 can no longer be accessed at the supplied link…I searched through the support portal and could not find a replacement so I don’t know if they pulled the KB documenting this issue entirely or if it’s been merged into another.  I did however find a support bulletin from June 2015 saying that the VAAI improvements had been added into the .217 firmware.  At one point I did request the .217 firmware only to find out they’d pulled it due to some issue it was causing.  I can only assume the VAAI improvements would’ve been added into some subsequent firmware version but no longer have my VNX’s in production, nor are they under support, and I won’t be able to personally test.

Hopefully this information will be beneficial to someone at there…luckily I found my way through the rabbit hole, but there wasn’t a whole lot publicly available regarding this issue when I was initially seeking a cause.